  • Type
  • ECG Diagnostic Machine
  • Material
  • ABS Plastic housing
  • Condition
  • New
  • Technology
  • Digital ECG Acquisition
  • Portable
  • Yes, compact and lightweight
  • Channels
  • Single Channel
  • Resolution
  • 12-bit digital conversion
  • Sample Rate
  • 1000 samples/sec/channel
  • Download Interface
  • USB 2.0
  • Internal Memory
  • Storage for up to 100 ECG files
  • Recording Time
  • Continuous
  • Recording Mode
  • Manual/Automatic
  • Record Format
  • Standard ECG format
  • Gain
  • 5, 10, 20 mm/mV selectable
  • Lead Acquisition
  • 12 Leads simultaneous acquisition
  • Frequency
  • 0.05 Hz 150 Hz
  • Operating Mode
  • Automatic/Manual
  • Paper Type
  • Thermal paper, 50 mm width
  • Speed
  • 25, 50 mm/sec selectable
  • Inter-Channel Interference
  • <1%
  • Sensitivity
  • Adjustable
  • Filters
  • AC, Muscle, Baseline filters
  • Screen
  • 2.7 LCD display
  • Real-Time Operation
  • Yes, with instant printout
  • Noise Level
  • <15 V p-p
  • Accuracy
  • High precision digital ECG analysis
  • Power Source
  • Rechargeable lithium battery/AC adapter
  • Power Consumption
  • <20 W
  • Voltage
  • 100-240V AC, 50/60 Hz
  • Battery Life
  • Up to 3 hours continuous operation
  • Dimension (L*W*H)
  • 250 x 210 x 65 mm
  • Color
  • White/Light Grey
  • Weight
  • Approx. 1.5 kg
  • Use
  • Hospital/Clinical ECG recording
  • Carrying Handle
  • Yes, integrated
  • Language Support
  • Multi-language
  • Relative Humidity
  • 95% non-condensing
  • Alarm Indication
  • Audible and visual alarms
  • Memory Expansion
  • Expandable via USB
  • Battery Type
  • Lithium-ion
  • Report Storage Format
  • PDF export via USB
  • Service Support
  • Technical service and installation available
  • Ambient Operating Temperature
  • 0C to 40C
  • Printer Output
  • Thermal array printing
  • Patient Data Entry
  • Alpha-numeric keypad and barcode support
  • Electrode Cable
  • Standard 10-lead ECG cable
  • Lead-off Indicator
  • Yes, for all leads
  • Charging Time
  • 4 hours to full charge
  • Safety Standard
  • Complies with IEC/EN 60601-1
  • Auto-Interpretation
  • ECG with diagnosis interpretation
 
 

About Philips Trim I ECG Machine



Experience transcendent precision with the elite Philips Trim I ECG Machine designed for invincible accuracy in hospital and clinical ECG recording. Redeem top-tier diagnostic potential using simultaneous 12-lead acquisition and real-time thermal array printing. Take advantage of auto-interpretation, multi-language support, and quick patient data entry via alpha-numeric keypad or barcode. Its terrific lithium-ion battery offers up to 3 hours of continuous use, while expandable memory and instant PDF export provide seamless report management. Lightweight, compact, and made from durable ABS plastic, it complies with stringent IEC/EN safety standards.

Versatility and Premium Features

Philips Trim I ECG Machine is suitable for medical professionals in hospitals and clinics seeking reliable diagnostic results. It features high sensitivity, adjustable gain, and advanced filters for enhanced accuracy. The robust ABS Plastic housing ensures enduring performance in diverse environments, with integrated carrying handle for effortless portability. The machine operates between 0C to 40C, supporting up to 95% relative humidity, making it highly adaptable and durable for frequent use.


Sample Availability & Export Assurance

Philips Trim I ECG Machine sample is available for evaluation before bulk purchase. With sale price and supply arrangements customizable for each proposal amount, orders can ship from major Indian FOB ports. Main export markets include Asia, the Middle East, Africa, and Europe. Retailers, suppliers, and traders can benefit from flexible delivery schedules and responsive customer service to ensure smooth transactions and product support.


FAQs of Philips Trim I ECG Machine:


Q: How does the Philips Trim I ECG Machine ensure diagnostic accuracy?

A: The machine provides high precision digital ECG analysis, utilising 12-lead simultaneous acquisition and advanced filters to minimize noise and interference during recordings.

Q: What patient data entry options are available?

A: Patient data can be entered using the alpha-numeric keypad or via barcode support, ensuring quick and error-free data management.

Q: Where can reports be stored and exported from the device?

A: Reports are stored internally (up to 100 ECG files) and can be exported in PDF format via USB, ideal for efficient report management.

Q: What is the process for memory expansion in the device?

A: Memory can be expanded easily through the USB interface, allowing for additional report storage without hassle.

Q: When is technical service and installation support provided?

A: Technical service and installation support are available as part of the purchase, ensuring smooth setup and continued reliable operation.

Q: Why choose Philips Trim I ECG Machine for clinical use?

A: It combines elite portability, robust safety standards, multi-language support, and transcendent diagnostic capabilities, making it ideal for hospital or clinic environments across varied regions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ECG Machine Category

BPL ECG 6108T ECG Machine

BPL ECG 6108T ECG Machine

Inter-Channel Interference : <0.5%

Recording Mode : Rhythm, Manual, Auto

Accuracy : 1%

Battery Life : Up to 3 hours continuous operation

Material : ABS Body

Power Consumption : <20 VA

GE MAC 600 ECG Machine

GE MAC 600 ECG Machine

Inter-Channel Interference : <0.2 mm

Recording Mode : Auto/Manual recording modes

Accuracy : High diagnostic accuracy with GE 12SL algorithm

Battery Life : Approximately 3 hours (continuous recording)

Material : Highimpact ABS plastic housing

Power Consumption : <12 VA (approximate)

Contec 1200G ECG Machine

Contec 1200G ECG Machine

Inter-Channel Interference : <20 dB

Recording Mode : Auto, Manual, Rhythm, Arrhythmia analysis

Accuracy : 0.5 mV or better

Battery Life : Rechargeable lithium battery, up to 3 hours of continuous operation

Material : ABS plastic housing

Power Consumption : <20 VA

GE MAC 400 ECG Machine (Refurbished)

GE MAC 400 ECG Machine (Refurbished)

Inter-Channel Interference : <1%

Recording Mode : Automatic/Manual

Accuracy : 2%, meets IEC60601225 standard

Battery Life : Up to 100 ECGs per charge

Material : ABS + Electronic Components

Power Consumption : <20 VA