Back to top
GE RT3200 Advantage II X
GE RT3200 Advantage II X

GE RT3200 Advantage II X

GE RT3200 Advantage II X Specification

  • Application
  • Medical Diagnostic Imaging
  • Temperature Range
  • 10C to 40C (Operation)
  • Material
  • High-Quality Metal and Polymer
  • Suitable For
  • Hospitals, Diagnostic Centers
  • Accuracy
  • High Accuracy Image Capture
  • Treatment Type
  • Diagnostic Radiography
  • Dimension (L*W*H)
  • 2000 mm x 800 mm x 1900 mm
  • Product Type
  • X-Ray Machine
  • Display Type
  • Digital
  • Height
  • 1900 mm
  • Shape
  • Rectangular Gantry with Floor Mount
  • Power
  • 5.0 kW
  • Function
  • Real-time Imaging, Image Storage
  • Humidity Range
  • 30% - 75% Relative Humidity
  • Weight
  • Approx. 450 kg
  • Phase
  • Single Phase
  • Use
  • Routine Radiography Exams
  • Frequency
  • 50/60 Hz
  • Storage Capacity
  • Digital Cassette - Images Stored Electronically
  • Automation Grade
  • Semi-Automatic
  • Color Code
  • GE Grey/Off-White
  • Properties
  • High Image Quality, Digital Processing, User-Friendly Interface
  • Voltage
  • 220-240 VAC
  • Display
  • LCD Control Console
  • Power Source
  • Electric
  • Mobility
  • Portable, Mounted on Wheels
  • Software Compatibility
  • DICOM Ready
  • Exposure Time Range
  • 0.01 sec to 6.3 sec
  • Safety Features
  • Overload Protection, Auto Shutdown
  • Maximum Tube Voltage
  • 110 kV
  • Image Processing
  • Digital Enhancement Supported
  • Maximum Output Power
  • 3200 W
  • Maximum Tube Current
  • 100 mA
  • Cable Length
  • 3 meters standard
  • Cooling System
  • Forced Air
  • Interface
  • USB, Ethernet
  • Control System
  • Microprocessor based
 
 

About GE RT3200 Advantage II X



The GE RT3200 Advantage II X delivers matchless diagnostic imaging with sensational savings in both efficiency and output. Distinguished by its magnificent design and ephemeral operation times, this system generates a maximum output power of 3200 W and an image quality thats highlighted by digital enhancement and high accuracy capture. Portable and mounted on wheels, it suits dynamic hospital environments. Featuring advanced microprocessor control, auto shutdown, overload protection, and DICOM-ready software compatibility, it fosters safe, reliable, and user-friendly radiography exams. The robust metal-polymer build ensures long-term durability.

Site of Application and Usage Directions

The GE RT3200 Advantage II X is ideally suited for hospitals and diagnostic centers. For standard operation, the device should be installed in dedicated radiography rooms. Users must position the system on a flat surface, utilizing its wheels for mobility. The rectangular gantry should face the patient area, with proper alignment for optimal imaging results. Application surface involves conventional radiography tables, ensuring accurate image capture during routine diagnostic procedures.


Supply Ability and Export Market Delivery

GE RT3200 Advantage II X is supplied efficiently, meeting large order demands across main export markets including Asia and India. With streamlined transportation, the system is delivered promptly to hospitals and diagnostic centers. The stipulated delivery time is minimized through advanced logistics, ensuring every unit arrives safely and securely. Our robust supply chain can accommodate bulk exports, supporting the needs of retailers, suppliers, and traders alike for seamless market integration.


FAQs of GE RT3200 Advantage II X:


Q: How does the GE RT3200 Advantage II X improve diagnostic imaging efficiency?

A: The system uses advanced microprocessor control and digital enhancement, resulting in fast exposure times and high accuracy image capture. Its automated processes reduce manual intervention and deliver consistent, clear images for routine radiography exams.

Q: What safety features are integrated in the GE RT3200 Advantage II X?

A: This device includes overload protection and auto shutdown functionality, ensuring user safety and protection of internal components during operation. The forced air cooling system further prevents overheating during prolonged use.

Q: When should routine maintenance be performed on this radiography system?

A: Routine maintenance should be scheduled as per the manufacturers recommended intervals, typically every six months or after extended continuous use to ensure optimal performance and longevity.

Q: Where can the GE RT3200 Advantage II X be installed for optimal usage?

A: The system is best installed in medical imaging suites, diagnostic centers, or hospital radiography rooms with controlled environmental conditions and proper grounding to maximize safety and imaging effectiveness.

Q: What is the process for saving and storing captured images?

A: Images are processed digitally and stored electronically via the digital cassette system. The device supports DICOM-ready software compatibility, enabling users to export, transfer, and archive images effortlessly using USB or Ethernet interfaces.

Q: How is the GE RT3200 Advantage II X transported and delivered to clients?

A: The unit is securely packed and shipped using specialized transportation methods, ensuring safe delivery to export markets. Delivery times are optimized, allowing hospitals and healthcare providers timely access to the system.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Radiology Products Category

X Ray Machines

X Ray Machines

Power Source : Electric

Function : Diagnostic Imaging

Weight : Approx. 400 kg

Frequency : 50 Hz

Use : Diagnostic Imaging

Automation Grade : SemiAutomatic

X- Ray Machine Multimobil 2.5

X- Ray Machine Multimobil 2.5

Power Source : Electric

Function : Portable Xray imaging

Weight : Lightweight portable

Frequency : 50 Hz

Use : Radiographic imaging

Automation Grade : SemiAutomatic

Medical Printers

Medical Printers

Power Source : Electric

Function : Medical Print Output

Weight : 4.5 kg

Frequency : 5060 Hz

Use : Printing medical reports and imaging scans

Automation Grade : SemiAutomatic

X Ray Tubes

X Ray Tubes

Power Source : External electrical supply

Function : Xray emission for various applications

Weight : Varies (approximately 13 kg)

Frequency : 5060 Hz

Use : Produces Xrays for imaging applications

Automation Grade : Manual or semiautomated usage